Download Print this page

Siemens SINAMICS G120 List Manual page 648

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

2 Parameters
2.2 List of parameters
p20181
PST 0 run-time group / PST 0 RTG
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: T
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
5
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Setting parameter for the run-time group in which the instance PST 0 of the pulse extension element is to be called.
Value:
5:
6:
9999: Do not calculate
p20182
PST 0 run sequence / PST 0 RunSeq
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: T
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
0
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Setting parameter for the run sequence of instance PST 0 within the run-time group set in p20181.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20183[0...1]
BI: PST 1 inputs / PST 1 inputs
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: T
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
-
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Sets the signal source for input pulse I and the reset input R of instance PST 1 of the pulse extension element.
Index:
[0] = Input pulse I
[1] = Reset input R
p20184
PST 1 pulse duration in ms / PST 1 pulse_dur ms
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: T
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
0.00
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Setting parameter for pulse duration T in milliseconds of instance PST 1 of the pulse extension element.
648
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Calculated: -
Scaling: -
Unit selection: -
Max
7999
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
5400000.00
Data type: Integer16
Dyn. index: -
Func. diagram: 7234
Factory setting
9999
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7234
Factory setting
490
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 7234
Factory setting
0
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7234
Factory setting
0.00