p0015
Macro drive unit / Macro drv unit
CU250S_V
Access level: 1
CU250S_V_CAN
Can be changed: C, C(1)
Unit group: -
Min
0
Description:
Runs the corresponding macro files.
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in r3996.
Modifications can be made again when r3996 = 0.
When executing a specific macro, the corresponding programmed settings are made and become active.
Note:
Macros available as standard are described in the technical documentation of the particular product.
r0018
Control Unit firmware version / Firmware version
Access level: 3
Can be changed: -
Unit group: -
Min
0
Description:
Displays the firmware version of the Control Unit.
Dependency:
Refer to: r0148, r0197, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
r0020
Speed setpoint smoothed / Speed setpoint
Access level: 2
Can be changed: -
Unit group: 3_1
Min
- [rpm]
Description:
Displays the currently smoothed speed setpoint at the input of the speed controller or U/f characteristic (after the
interpolator).
Dependency:
Refer to: r0060
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The speed setpoint is available smoothed (r0020) and unsmoothed (r0060).
r0021
CO: Actual speed smoothed / Actual speed
Access level: 2
Can be changed: -
Unit group: 3_1
Min
- [rpm]
Description:
Displays the calculated and smoothed rotor speed.
Frequency components from the slip compensation (for induction motors) are not included.
Dependency:
Refer to: r0022, r0063
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The speed actual value is available smoothed (r0021, r0022) and unsmoothed (r0063).
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: -
Unit selection: -
Max
999999
Calculated: -
Scaling: -
Unit selection: -
Max
4294967295
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
12
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 5020, 6799
Factory setting
- [rpm]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6799
Factory setting
- [rpm]
27

Hide quick links:

Advertisement

loading