Download Print this page

Siemens SINAMICS G120 List Manual page 332

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

2 Parameters
2.2 List of parameters
[12] = Bit 12
[13] = Bit 13
[14] = Bit 14
[15] = Bit 15
Dependency:
Refer to: p2088, r2089
p2084[0...15]
BI: Binector-connector converter status word 5 / Bin/con ZSW5
Access level: 3
Can be changed: U, T
Unit group: -
Min
-
Description:
Selects bits to be sent to the PROFIdrive controller.
The individual bits are combined to form free status word 5.
Index:
[0] = Bit 0
[1] = Bit 1
[2] = Bit 2
[3] = Bit 3
[4] = Bit 4
[5] = Bit 5
[6] = Bit 6
[7] = Bit 7
[8] = Bit 8
[9] = Bit 9
[10] = Bit 10
[11] = Bit 11
[12] = Bit 12
[13] = Bit 13
[14] = Bit 14
[15] = Bit 15
Dependency:
Refer to: p2088, r2089
p2088[0...4]
Invert binector-connector converter status word / Bin/con ZSW inv
CU250S_V_DP
Access level: 3
CU250S_V_PN
Can be changed: U, T
Unit group: -
Min
-
Description:
Setting to invert the individual binector inputs of the binector-connector converter.
Index:
[0] = Status word 1
[1] = Status word 2
[2] = Free status word 3
[3] = Free status word 4
[4] = Free status word 5
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
332
Signal name
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 2472
Factory setting
0
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2472
Factory setting
[0] 1010 1000 0000 0000 bin
[1...4] 0000 0000 0000 0000 bin
0 signal
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
FP
-
-
-
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

loading