2 Parameters
2.2 List of parameters
p2213[0...n]
CO: Technology controller fixed value 13 / Tec_ctr fix val 13
CU250S_V (Tech_ctrl)
Access level: 2
CU250S_V_CAN
Can be changed: U, T
(Tech_ctrl)
Unit group: 9_1
CU250S_V_DP
Min
(Tech_ctrl)
-200.00 [%]
CU250S_V_PN
(Tech_ctrl)
Description:
Sets the value for fixed value 13 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2214[0...n]
CO: Technology controller fixed value 14 / Tec_ctr fix val 14
CU250S_V (Tech_ctrl)
Access level: 2
CU250S_V_CAN
Can be changed: U, T
(Tech_ctrl)
Unit group: 9_1
CU250S_V_DP
Min
(Tech_ctrl)
-200.00 [%]
CU250S_V_PN
(Tech_ctrl)
Description:
Sets the value for fixed value 14 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2215[0...n]
CO: Technology controller fixed value 15 / Tec_ctr fix val 15
CU250S_V (Tech_ctrl)
Access level: 2
CU250S_V_CAN
Can be changed: U, T
(Tech_ctrl)
Unit group: 9_1
CU250S_V_DP
Min
(Tech_ctrl)
-200.00 [%]
CU250S_V_PN
(Tech_ctrl)
Description:
Sets the value for fixed value 15 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2216[0...n]
Technology controller fixed value selection method / Tec_ctr FixVal sel
CU250S_V (Tech_ctrl)
Access level: 2
CU250S_V_CAN
Can be changed: T
(Tech_ctrl)
Unit group: -
CU250S_V_DP
Min
(Tech_ctrl)
1
CU250S_V_PN
(Tech_ctrl)
Description:
Sets the method to select the fixed setpoints.
Value:
1:
2:
p2220[0...n]
BI: Technology controller fixed value selection bit 0 / Tec_ctrl sel bit 0
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source to select a fixed value of the technology controller.
Dependency:
Refer to: p2221, p2222, p2223
366
Direct selection
Binary selection
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: -
Unit selection: -
Max
2
Calculated: -
Scaling: -
Unit selection: -
Max
-
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7950
Factory setting
130.00 [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7950
Factory setting
140.00 [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7950
Factory setting
150.00 [%]
Data type: Integer16
Dyn. index: DDS, p0180
Func. diagram: 7950, 7951
Factory setting
1
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 7950, 7951
Factory setting
0
SINAMICS G120 CU250S-2 Control Units