Download Print this page

Siemens SINAMICS G120 List Manual page 287

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

r1762[0...1]
Motor model deviation component 1 / MotMod dev comp 1
Access level: 4
Can be changed: -
Unit group: -
Min
-
Description:
Induction motor (ASM):
Displays the referred imaginary system deviation for the adaptation circuit of the motor model.
Permanent-magnet synchronous motor (PMSM):
Displays the system deviation for speed adaptation.
r1762[0]: Angular deviation [rad-el] of the estimated EMF.
r1762[1]: Angular deviation [rad-el] of the low-level signal response for pulse technique.
Index:
[0] = Deviation model 1
[1] = Deviation model 2
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1), "Dynamic Drive Control" (DDC, p0096
= 2)
r1763
Motor model deviation component 2 / MotMod dev comp 2
Access level: 4
Can be changed: -
Unit group: -
Min
-
Description:
Induction motor (ASM):
Displays the referred real system deviation for the adaptation circuit of the motor model.
Permanent-magnet synchronous motor (PMSM):
Not used.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1), "Dynamic Drive Control" (DDC, p0096
= 2)
p1764[0...n]
Motor model without encoder speed adaptation Kp / MotMod woE n_adaKp
Access level: 4
Can be changed: U, T
Unit group: -
Min
0.000
Description:
Sets the proportional gain of the controller for speed adaptation without encoder.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
r1765
Motor model speed adaptation Kp effective / MotM n_ada Kp act
Access level: 4
Can be changed: -
Unit group: -
Min
-
Description:
Displays the effective proportional gain of the controller for the speed adaptation.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: p0340 = 1,3,4
Scaling: -
Unit selection: -
Max
100000.000
Calculated: -
Scaling: p2001
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6721, 6730, 6731
Factory setting
-
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6730
Factory setting
1000.000
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
-
287