Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

Bit field:
Bit
00
01
02
03
04
11
12
13
Dependency:
Refer to: F07988
Note:
The encoder is only tested if the rotating measurement with encoder is selected (p1960 = 2).
The following parameters are influenced for the individual optimization steps:
Bit 00: None
Bit 01: p0320, p0360, p0362 ... p0369
Bit 02: p0341, p0342
Bit 03: p1400.0, p1458, p1459, p1460, p1462, p1463, p1470, p1472, p1496
Bit 04: Dependent on p1960
Bit 05: p0391, p0392, p0393, p1402.2 only for induction motors
p1960 = 1, 3: p1458, p1459, p1470, p1472, p1496, p1400.0
p1960 = 2, 4: p1458, p1459, p1460, p1462, p1496, p1461, p1463
The identification of the q leakage inductance can only be carried out for unloaded motors or motors with a low load
(load approx. 30% below the rated motor torque). Only then is a current controller adaptation (p0391 ... p0393)
parameterized if the q-leakage inductance under no-load conditions is at least 30 % higher than the total leakage
inductance (p0356, p0358).
p1959[0...n]
Rotating measurement configuration / Rot meas config
PM250
Access level: 3
PM260
Can be changed: T
Unit group: -
Min
-
Description:
Sets the configuration of the rotating measurement.
Bit field:
Bit
00
01
02
03
04
11
Dependency:
Refer to: F07988
Note:
The encoder is only tested if the rotating measurement with encoder is selected (p1960 = 2).
The following parameters are influenced for the individual optimization steps:
Bit 00: None
Bit 01: p0320, p0360, p0362 ... p0369
Bit 02: p0341, p0342
Bit 03: p1400.0, p1458, p1459, p1460, p1462, p1463, p1470, p1472, p1496
Bit 04: Dependent on p1960
Bit 05: p0391, p0392, p0393, p1402.2 only for induction motors
p1960 = 1, 3: p1458, p1459, p1470, p1472, p1496, p1400.0
p1960 = 2, 4: p1458, p1459, p1460, p1462, p1496, p1461, p1463
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Signal name
Encoder test active
Saturation characteristic identification
Moment of inertia identification
Re-calculates the speed controller
parameters
Speed controller optimization (vibration test) Yes
Do not change the controller parameters
during the measurement
Measurement shortened
After measurement direct transition into
operation
Signal name
Encoder test active
Saturation characteristic identification
Moment of inertia identification
Re-calculates the speed controller
parameters
Speed controller optimization (vibration test) Yes
Do not change the controller parameters
during the measurement
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
0 signal
No
No
No
No
No
No
No
No
Data type: Unsigned16
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
0000 0000 0001 1111 bin
0 signal
No
No
No
No
No
No
FP
-
-
-
-
-
-
-
-
FP
-
-
-
-
-
-
305