2 Parameters
2.2 List of parameters
31:
32:
33:
36:
37:
60:
61:
62:
63:
66:
67:
70:
71:
72:
73:
76:
77:
200:
Dependency:
When changing this parameter, the following settings are influenced:
Refer to: p1070, p1071, p1075, p1076
Caution:
If p1000 is selected as the main setpoint of the fieldbus, the following BICO interconnection is set automatically:
p2051[1] = r0063
Notice:
The parameter is possibly protected as a result of p0922.
For PROFIBUS/PROFINET Control Units, the following applies: The parameter can be freely set by setting p0922 =
999.
When executing a specific macro, the corresponding programmed settings are made and become active.
p1000[0...n]
Speed setpoint selection / n_set sel
CU250S_V
Access level: 1
CU250S_V_CAN
Can be changed: T
Unit group: -
Min
0
Description:
Sets the source for the speed setpoint.
For single-digit values, the following applies:
The value specifies the main setpoint.
For double-digit values, the following applies:
The left-hand digit specifies the supplementary setpoint, the right-hand digit the main setpoint.
Example:
Value = 26
--> The analog setpoint (2) supplies the supplementary setpoint.
--> The fieldbus (6) supplies the main setpoint.
Value:
0:
1:
2:
3:
6:
7:
10:
11:
12:
13:
16:
17:
20:
21:
180
Fixed speed setpoint + motor potentiometer
Fixed speed setpoint + analog setpoint
Fixed speed setpoint + fixed speed setpoint
Fixed speed setpoint + fieldbus
Fixed speed setpoint + analog setpoint 2
Fieldbus + no main setpoint
Fieldbus + motor potentiometer
Fieldbus + analog setpoint
Fieldbus + fixed speed setpoint
Fieldbus+fieldbus
Fieldbus + analog setpoint 2
Analog setpoint 2 + no main setpoint
Analog setpoint 2 + motor potentiometer
Analog setpoint 2 + analog setpoint
Analog setpoint 2 + fixed speed setpoint
Analog setpoint 2 + fieldbus
Analog setpoint 2 + analog setpoint 2
Analog output connection
No main setpoint
Motorized potentiometer
Analog setpoint
Fixed speed setpoint
Fieldbus
Analog setpoint 2
Motor potentiometer + no main setpoint
Motor potentiometer + motor potentiometer
Motor potentiometer + analog setpoint
Motor potentiometer + fixed speed setpoint
Motor potentiometer + fieldbus
Motor potentiometer + analog setpoint 2
Analog setpoint + no main setpoint
Analog setpoint + motor potentiometer
Calculated: -
Scaling: -
Unit selection: -
Max
200
Data type: Integer16
Dyn. index: CDS, p0170
Func. diagram: -
Factory setting
[0] 2
[1] 0
[2] 0
[3] 0