Siemens SINAMICS G120 List Manual page 569

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

p9670
SI module identification Control Unit / Module ID CU
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
CRC via Node Identifier of the Control Unit.
Note:
CU: Control Unit
p9672
SI module identifier Power Module / Module ID PM
Access level: 3
Can be changed: C(95), T
Unit group: -
Min
0
Description:
CRC via the Node Identifier of a Power Module.
Note:
PM: Power Module
p9700
SI copy function / SI copy function
Access level: 3
Can be changed: C(95), U, T
Unit group: -
Min
0000 hex
Description:
Setting to start the required copy function.
After starting, the corresponding parameters are copied from processor 1 to processor 2.
Once copying is complete, the parameter is automatically reset to zero.
Value:
0:
29:
87:
208:
Dependency:
Refer to: r3996
Notice:
When the parameters are copied, short-term communication interruptions may occur.
Note:
For value = 57 hex and D0 hex:
The value can only be set if the safety commissioning mode is set and the Safety Integrated password was entered.
For value = D0 hex:
The following parameters are copied after starting the copy function:
p9601 --> p9801, p9610 --> 9810, p9650 --> p9850, p9651 --> p9851
p9701
Acknowledge SI data change / Ackn SI data
Access level: 3
Can be changed: C(95), U, T
Unit group: -
Min
0000 hex
Description:
Setting to transfer the reference checksums from the associated actual checksums after changes (SI parameters,
hardware).
After transferring the reference checksums, parameters are automatically reset to zero.
Value:
0:
172:
220:
236:
Dependency:
Refer to: r9398, p9399, r9728, p9729, r9798, p9799, r9898, p9899
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
[00 hex] Copy function ended
[1D hex] Start copy function node identifier
[57 hex] Start copy function SI parameters
[D0 hex] Start copy function SI basic parameters
[00 hex] Data unchanged
[AC hex] Acknowledge data change complete
[DC hex] Acknowledge SI basic parameter change
[EC hex] Acknowledge hardware CRC
Calculated: -
Scaling: -
Unit selection: -
Max
4294967295
Calculated: -
Scaling: -
Unit selection: -
Max
4294967295
Calculated: -
Scaling: -
Unit selection: -
Max
00D0 hex
Calculated: -
Scaling: -
Unit selection: -
Max
00EC hex
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0000 hex
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0000 hex
569