2 Parameters
2.2 List of parameters
p9558
SI Motion acceptance test mode time limit (processor 1) / SI Mtn acc t P1
Access level: 3
Can be changed: C(95)
Unit group: -
Min
5000.00 [ms]
Description:
Sets the maximum time for the acceptance test mode.
If the acceptance test mode takes longer than the selected time limit, then the mode is automatically terminated.
Dependency:
Refer to: C01799
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
p9559
SI Motion forced checking procedure timer (processor 1) / SI Mtn dyn timer
Access level: 3
Can be changed: C(95)
Unit group: -
Min
0.00 [h]
Description:
Sets the time interval for carrying out the forced checking procedure and testing the safety motion monitoring
functions integrated in the drives.
Within the parameterized time, the safety functions must have been tested at least once (including de-selection of the
"STO" function).
This monitoring time is reset each time the test is carried out.
The signal source to initiate the forced checking procedure is set in p9705.
Dependency:
Refer to: p9705
Refer to: A01697, C01798
Note:
STO: Safe Torque Off
p9560
SI Motion pulse suppression shutdown speed (processor 1) / SI Mtn IL v_sh P1
Access level: 3
Can be changed: C(95)
Unit group: -
Min
10.00 [rpm]
Description:
Sets the shutdown speed for the pulse suppression.
Below this speed "standstill" is assumed and for STOP B / SS1, the pulses are suppressed (by changing to STOP A).
Dependency:
Refer to: p9556
Note:
The shutdown speed has no effect for a value = 0.
SS1: Safe Stop 1
p9563[0...3]
SI Motion SLS-specific stop response (processor 1) / SI Mtn SLS stop P1
Access level: 3
Can be changed: C(95)
Unit group: -
Min
0
Description:
Sets the SLS-specific stop response for the function "Safely Limited Speed" (SLS).
These settings apply to the individual limit values for SLS.
Value:
0:
1:
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLS4
560
STOP A
STOP B
Calculated: -
Scaling: -
Unit selection: -
Max
100000.00 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
9000.00 [h]
Calculated: -
Scaling: -
Unit selection: -
Max
6000.00 [rpm]
Calculated: -
Scaling: -
Unit selection: -
Max
1
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
40000.00 [ms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
8.00 [h]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
10.00 [rpm]
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890