Download Print this page

Siemens SINAMICS G120 List Manual page 924

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

n_set before filt. [rpm]
r0060
[6799.1]
Speed setpoint sum [rpm]
r1170
[3080.8]
n_limit pos eff [rpm]
r1084
[3050.8]
n_limit neg eff [rpm]
r1087
[3050.8]
1
2
Vector control, Dynamic Drive Control
Speed setpoint, Pre-control balancing, acceleration model (p0096 = 2)
M_inert tot scal [kgm²]
r1493
[6823.8]
ZSW n_ctrl
r1407
r1407
.11
[2522.3]
n_set_filt 1 T
0.00 ... 5000.00 [ms]
p1416 [D] (0.00)
n_set after filter [rpm]
r0062
1 = Sensorless vector control, speed pre-control active
n_ctrl config
p1400
.15
0
0
1
3
4
ZSW cl-loop ctrl
r0056
[2526.6]
r0056
Acceleration calculation
n_C n_act T_s SL
0.00 ... 32000.00 [ms]
p1452 [D] (10.00)
Pre-control balancing
5
fp_6822_97_56.vsd
05.09.2017
.14
1
0
Calculated accelerating torque
0
a_prectrl scal
0.0 ... 10000.0 [%]
p1496 [D] (0.0)
>0
n_ctrl n_set [rpm]
0
Pre-control speed
6
7
Function diagram
G120 CU250S-2
V4.7.9
[6826.1]
r1438
[6824.1]
[6841.1]
[6842.1]
8
- 6822 -

Hide quick links:

Advertisement

loading