Download Print this page

Siemens SINAMICS G120 List Manual page 369

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

r2231
Technology controller motorized potentiometer setpoint memory / Tec_ctrl mop mem
CU250S_V (Tech_ctrl)
Access level: 3
CU250S_V_CAN
Can be changed: -
(Tech_ctrl)
Unit group: 9_1
CU250S_V_DP
Min
(Tech_ctrl)
- [%]
CU250S_V_PN
(Tech_ctrl)
Description:
Displays the setpoint memory for the motorized potentiometer of the technology controller.
For p2230.0 = 1, the last setpoint that was saved is entered after ON.
Dependency:
Refer to: p2230
p2235[0...n]
BI: Technology controller motorized potentiometer raise setpoint / Tec_ctrl mop raise
CU250S_V (Tech_ctrl)
Access level: 3
CU250S_V_CAN
Can be changed: T
(Tech_ctrl)
Unit group: -
CU250S_V_DP
Min
(Tech_ctrl)
-
CU250S_V_PN
(Tech_ctrl)
Description:
Sets the signal source to continually increase the setpoint for the motorized potentiometer of the technology
controller.
The setpoint change (CO: r2250) depends on the set ramp-up time (p2247) and the duration of the signal that is
present (BI: p2235).
Dependency:
Refer to: p2236
p2236[0...n]
BI: Technology controller motorized potentiometer lower setpoint /
Tec_ctrl mop lower
CU250S_V (Tech_ctrl)
Access level: 3
CU250S_V_CAN
Can be changed: T
(Tech_ctrl)
Unit group: -
CU250S_V_DP
Min
(Tech_ctrl)
-
CU250S_V_PN
(Tech_ctrl)
Description:
Sets the signal source to continually reduce the setpoint for the motorized potentiometer of the technology controller.
The setpoint change (CO: r2250) depends on the set ramp-down time (p2248) and the duration of the signal that is
present (BI: p2236).
Dependency:
Refer to: p2235
p2237[0...n]
Technology controller motorized potentiometer maximum value / Tec_ctrl mop max
CU250S_V (Tech_ctrl)
Access level: 3
CU250S_V_CAN
Can be changed: U, T
(Tech_ctrl)
Unit group: 9_1
CU250S_V_DP
Min
(Tech_ctrl)
-200.00 [%]
CU250S_V_PN
(Tech_ctrl)
Description:
Sets the maximum value for the motorized potentiometer of the technology controller.
Dependency:
Refer to: p2238
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: -
Unit selection: p0595
Max
- [%]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: p0595
Max
200.00 [%]
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7954
Factory setting
- [%]
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 7954
Factory setting
0
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 7954
Factory setting
0
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7954
Factory setting
100.00 [%]
369