2 Parameters
2.2 List of parameters
p20061
OR 3 run sequence / OR 3 RunSeq
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: T
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
0
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Setting parameter for the run sequence of instance OR 3 within the run-time group set in p20060.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20062[0...3]
BI: XOR 0 inputs / XOR 0 inputs
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: T
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
-
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Sets the signal source of input quantities I0, I1, I2, I3 of instance XOR 0 of the XOR function block.
Index:
[0] = Input I0
[1] = Input I1
[2] = Input I2
[3] = Input I3
r20063
BO: XOR 0 output Q / XOR 0 output Q
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: -
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
-
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Display parameter for binary quantity Q of instance XOR 0 of the XOR function block.
p20064
XOR 0 run-time group / XOR 0 RTG
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: T
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
1
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Setting parameter for the run-time group in which the instance XOR 0 of the XOR function block is to be called.
Value:
1:
2:
3:
4:
5:
6:
9999: Do not calculate
618
Run-time group 1
Run-time group 2
Run-time group 3
Run-time group 4
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
32000
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7212
Factory setting
90
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 7214
Factory setting
0
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7214
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7214
Factory setting
9999