r0394[0...n]
Rated motor power / Mot P_rated
Access level: 3
Can be changed: -
Unit group: 14_6
Min
- [kW]
Description:
Displays the rated motor power.
Note:
The parameter displays p0307. For p0307 = 0, r0394 is calculated from p0304 and p0305 (only for induction motors).
Depending on the actual motor type, deviations can occur from the actual rated motor power.
r0395[0...n]
Actual stator resistance / R_stator act
Access level: 3
Can be changed: -
Unit group: -
Min
- [ohm]
Description:
Displays the actual stator resistance (phase value).
The parameter value also contains the temperature-independent cable resistance.
Dependency:
In the case of induction motors the parameter is also affected by the motor temperature model.
Refer to: p0350, p0352, p0620
Note:
In each case, only the stator resistance of the active Motor Data Set is included with the stator temperature of the
thermal motor model.
r0396[0...n]
Actual rotor resistance / R_rotor act
Access level: 3
Can be changed: -
Unit group: -
Min
- [ohm]
Description:
Displays the actual rotor resistance (phase value).
The parameter is affected by the motor temperature model.
Dependency:
Refer to: p0354, p0620
Note:
In each case, only the rotor resistance of the active Motor Data Set is included with the rotor temperature of the
thermal motor model.
This parameter is not used for synchronous motors (p0300 = 2xx).
p0397[0...n]
Angle magnetic decoupling maximum angle / Magn decpl max_ang
Access level: 4
Can be changed: U, T
Unit group: -
Min
0.0 [°]
Description:
Maximum angle when calculating the polynomial function to decouple the magnetic flux axes for permanent-magnet
synchronous motors (see p0398, p0399).
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: -
Unit selection: p0100
Max
- [kW]
Calculated: -
Scaling: -
Unit selection: -
Max
- [ohm]
Calculated: -
Scaling: -
Unit selection: -
Max
- [ohm]
Calculated: p0340 = 1,2
Scaling: -
Unit selection: -
Max
90.0 [°]
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [kW]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [ohm]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [ohm]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
90.0 [°]