2 Parameters
2.2 List of parameters
r0633[0...n]
Mot_temp_mod rotor temperature / Mod rotor temp
Access level: 4
Can be changed: -
Unit group: 21_1
Min
- [°C]
Description:
Displays the rotor temperature of the motor temperature model (models 2 and 3).
Note:
For motor temperature model 1 (p0612.0 = 1), this parameter is not valid:
p0634[0...n]
Q flux flux constant unsaturated / PSIQ KPSI UNSAT
Access level: 3
Can be changed: C(3), U, T
Unit group: -
Min
0.000 [Vsrms]
Description:
The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
The parameter weights the unsaturated component of the quadrature axis flux function.
p0635[0...n]
Q flux quadrature axis current constant unsaturated / PSIQ KIQ UNSAT
Access level: 3
Can be changed: C(3), U, T
Unit group: -
Min
0.00 [Arms]
Description:
The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
This parameter describes the interdependency of the unsaturated component of the quadrature axis current.
Dependency:
Refer to: p0634
p0636[0...n]
Q flux direct axis current constant unsaturated / PSIQ KID UNSAT
Access level: 3
Can be changed: C(3), U, T
Unit group: -
Min
0.00 [Arms]
Description:
The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
This parameter describes the interdependency of the unsaturated component of the direct axis current.
Dependency:
Refer to: p0634
p0637[0...n]
Q flux flux gradient saturated / PSIQ Grad SAT
Access level: 3
Can be changed: C(3), U, T
Unit group: -
Min
0.00 [mH]
Description:
The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
This parameter describes the gradients of the saturated component over the quadrature axis current.
Dependency:
Refer to: p0634, p0635, p0636
136
Calculated: -
Scaling: p2006
Unit selection: p0505
Max
- [°C]
Calculated: -
Scaling: -
Unit selection: -
Max
100.000 [Vsrms]
Calculated: -
Scaling: -
Unit selection: -
Max
10000.00 [Arms]
Calculated: -
Scaling: -
Unit selection: -
Max
10000.00 [Arms]
Calculated: -
Scaling: -
Unit selection: -
Max
10000.00 [mH]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: 8018
Factory setting
- [°C]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
0.000 [Vsrms]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
0.00 [Arms]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
0.00 [Arms]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
0.00 [mH]