r20361
BO: MFP 3 output Q / MFP 3 output Q
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: -
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
-
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Display parameter for output pulse Q of instance MFP 3 of the pulse generator.
p20362
MFP 3 run-time group / MFP 3 RTG
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: T
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
5
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Setting parameter for the run-time group in which the instance MFP 3 of the pulse generator is to be called.
Value:
5:
6:
9999: Do not calculate
p20363
MFP 3 run sequence / MFP 3 RunSeq
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: T
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
0
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Setting parameter for the run sequence of instance MFP 3 within the run-time group set in p20362.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20372
CI: PLI 0 input X / PLI 0 input X
CU250S_V
Access level: 3
(FBLOCKS)
Can be changed: T
CU250S_V_CAN
Unit group: -
(FBLOCKS)
Min
CU250S_V_DP
-
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Description:
Sets the signal source for input X of the polyline (20 breakpoints) of instance PLI 0.
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Calculated: -
Scaling: -
Unit selection: -
Max
32000
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7230
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7230
Factory setting
9999
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7230
Factory setting
960
Data type: U32 / FloatingPoint32
Dyn. index: -
Func. diagram: 7226
Factory setting
0