2 Parameters
2.2 List of parameters
05
06
07
08
09
10
11
12
13
14
15
Notice:
p2080 is used to define the signal sources of the PROFIdrive status word interconnection.
Note:
For bit 03:
This signal is inverted if it is interconnected to a digital output.
For r0052:
The status bits have the following sources:
Bit 00: r0899 Bit 0
Bit 01: r0899 Bit 1
Bit 02: r0899 Bit 2
Bit 03: r2139 Bit 3 (or r1214.10 for p1210 > 0)
Bit 04: r0899 Bit 4
Bit 05: r0899 Bit 5
Bit 06: r0899 Bit 6
Bit 07: r2139 Bit 7
Bit 08: r2197 Bit 7
Bit 09: r0899 Bit 7
Bit 10: r2197 Bit 6
Bit 11: r0056 Bit 13 (negated)
Bit 12: r0899 Bit 12
Bit 13: r2135 Bit 14 (negated)
Bit 14: r2197 Bit 3
Bit 15: r2135 Bit 15 (negated)
r0053.0...11
CO/BO: Status word 2 / ZSW 2
Access level: 2
Can be changed: -
Unit group: -
Min
-
Description:
Display and BICO output for status word 2.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
Notice:
p2081 is used to define the signal sources of the PROFIdrive status word interconnection.
38
Quick Stop active (OFF3)
Switching-on inhibited active
Alarm present
Deviation setpoint/actual speed
Control request
Maximum speed reached
I, M, P limit reached
Motor holding brake open
Alarm motor overtemperature
Motor rotates forwards
Alarm drive converter overload
Signal name
DC braking active
|n_act| > p1226 (n_standstill)
|n_act| > p1080 (n_min)
I_act >= p2170
|n_act| > p2155
|n_act| <= p2155
|n_act| >= r1119 (n_set)
Vdc <= p2172
Vdc > p2172
Ramp-up/ramp-down completed
Technology controller output at the lower
limit
Technology controller output at the upper
limit
No
Yes
Yes
No
Yes
Yes
No
Yes
No
Yes
No
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
No
Yes
No
Yes
No
Yes
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No