Signal targets for POS_ZSW (positioning mode)
Signal
POS_ZSW.0
1 = Tracking active
POS_ZSW.1
1 = Velocity limiting active
POS_ZSW.2
1 = Setpoint available
POS_ZSW.3
Reserved
1 = Axis moves forwards
POS_ZSW.4
0 = Axis stationary or moves backwards
1 = Axis moves backwards
POS_ZSW.5
0 = Axis stationary or moves forwards
POS_ZSW.6
1 = Software limit switch minus reached
POS_ZSW.7
1 = Software limit switch plus reached
1 = Position actual value ” cam switching position 1
POS_ZSW.8
0 = Overrun cam switching position 1
1 = Position actual value ” cam switching position 2
POS_ZSW.9
0 = Overrun cam switching position 2
POS_ZSW.10
1 = Direct output 1 via the traversing block
POS_ZSW.11
1 = Direct output 2 via the traversing block
POS_ZSW.12
1 = Fixed stop reached
POS_ZSW.13
1 = Fixed stop, clamping torque reached
POS_ZSW.14
1 = Travel to fixed stop active
POS_ZSW.15
Reserved
<1>
Used in telegram 110.
1
2
PROFIdrive (PROFIBUS/PROFINET), EtherNet/IP
PROFIdrive - POS_ZSW positioning status word interconnection
Meaning
3
4
Interconnection
[Function diagram]
parameters
internal control word
p2084[0] = r2683.0
-
p2084[1] = r2683.1
-
p2084[2] = r2683.2
-
-
-
p2084[4] = r2683.4
-
p2084[5] = r2683.5
-
p2084[6] = r2683.6
-
p2084[7] = r2683.7
-
p2084[8] = r2683.8
-
p2084[9] = r2683.9
-
p2084[10] = r2683.10
-
p2084[11] = r2683.11
-
p2084[12] = r2683.12
-
p2084[13] = r2683.13
-
p2084[14] = r2683.14
-
-
-
5
6
fp_2465_97_55.vsd
05.09.2017
V4.7.9
<1>
[Function diagram]
Inverted
signal target
[3645]
-
[3645]
-
[3645]
-
-
-
[3645]
-
[3645]
-
[3645]
-
[3645]
-
[3645]
-
[3645]
-
[3645]
-
[3645]
-
[3645]
-
[3645]
-
[3645]
-
-
-
7
8
Function diagram
- 2465 -
G120 CU250S-2 DP/PN

Hide quick links:

Advertisement

loading