Download Print this page

Siemens SINAMICS G120 List Manual page 359

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

p2188[0...n]
Load monitoring torque threshold 2 lower / M_thresh 2 lower
CU250S_V (Ext msg)
Access level: 3
CU250S_V_CAN (Ext
Can be changed: U, T
msg)
Unit group: 7_1
CU250S_V_DP (Ext
Min
msg)
0.00 [Nm]
CU250S_V_PN (Ext
msg)
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2188 < p2187
Refer to: p2183, p2187
Refer to: A07926
Note:
The lower envelope curve is defined by p2186, p2188 and p2190.
p2189[0...n]
Load monitoring torque threshold 3 upper / M_thresh 3 upper
CU250S_V (Ext msg)
Access level: 3
CU250S_V_CAN (Ext
Can be changed: U, T
msg)
Unit group: 7_1
CU250S_V_DP (Ext
Min
msg)
0.00 [Nm]
CU250S_V_PN (Ext
msg)
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2189 > p2190
Refer to: p2184, p2190
Refer to: A07926
Note:
The upper envelope curve is defined by p2185, p2187 and p2189.
p2190[0...n]
Load monitoring torque threshold 3 lower / M_thresh 3 lower
CU250S_V (Ext msg)
Access level: 3
CU250S_V_CAN (Ext
Can be changed: U, T
msg)
Unit group: 7_1
CU250S_V_DP (Ext
Min
msg)
0.00 [Nm]
CU250S_V_PN (Ext
msg)
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2190 < p2189
Refer to: p2184, p2189
Refer to: A07926
Note:
The lower envelope curve is defined by p2186, p2188 and p2190.
p2192[0...n]
Load monitoring delay time / Load monit t_del
CU250S_V (Ext msg)
Access level: 3
CU250S_V_CAN (Ext
Can be changed: U, T
msg)
Unit group: -
CU250S_V_DP (Ext
Min
msg)
0.00 [s]
CU250S_V_PN (Ext
msg)
Description:
Sets the delay time to evaluate the load monitoring.
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: -
Unit selection: p0505
Max
20000000.00 [Nm]
Calculated: -
Scaling: -
Unit selection: p0505
Max
20000000.00 [Nm]
Calculated: -
Scaling: -
Unit selection: p0505
Max
20000000.00 [Nm]
Calculated: -
Scaling: -
Unit selection: -
Max
65.00 [s]
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 8013
Factory setting
0.00 [Nm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 8013
Factory setting
10000000.00 [Nm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 8013
Factory setting
0.00 [Nm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 8013
Factory setting
10.00 [s]