p4674[0...n]
Analog sensor channel B voltage at actual value zero / Ana_sens B U at 0
Access level: 4
Can be changed: U, T
Unit group: -
Min
-10.0000 [V]
Description:
Sets the voltage when the connected sensor is at actual value zero.
At this voltage channel B supplies an actual value of zero.
p4675[0...n]
Analog sensor channel B voltage per encoder period / Ana_sens B U/per
Access level: 4
Can be changed: U, T
Unit group: -
Min
-10.0000 [V]
Description:
Sets the output voltage range to be mapped for the connected analog sensor.
The voltage range is determined by the following parameters:
- p4674 (voltage at actual value 0)
- p4675 (voltage per encoder period)
Note:
The minimum actual value which can be mapped is equal to p4674 - p4675/2.
The maximum actual value which can be mapped is equal to p4674 + p4675/2.
p4676[0...n]
Analog sensor range limit threshold / Ana_sens lim thr
Access level: 4
Can be changed: U, T
Unit group: -
Min
0.0 [%]
Description:
Sets the threshold for limit monitoring of the absolute actual value on the analog sensor.
If this threshold is overshot by the actual value of a channel, a corresponding fault/alarm (p4670.9) is output.
Dependency:
Refer to: p4673, p4675
p4677[0...n]
Analog sensor LVDT configuration / Ana_sens LVDT conf
Access level: 4
Can be changed: C(4)
Unit group: -
Min
-
Description:
Sets the configuration for LVDT mode on the analog sensor.
Bit field:
Bit
00
01
02
03
p4678[0...n]
Analog sensor LVDT ratio / An_sens LVDT ratio
Access level: 4
Can be changed: C(4)
Unit group: -
Min
0.00 [%]
Description:
Sets the ratio for the LVDT sensor.
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Signal name
LVDT ON
Track B excitation
Fixed value amplitude
Fixed value amplitude and phase
Calculated: -
Scaling: -
Unit selection: -
Max
10.0000 [V]
Calculated: -
Scaling: -
Unit selection: -
Max
10.0000 [V]
Calculated: -
Scaling: -
Unit selection: -
Max
100.0 [%]
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
200.00 [%]
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
0.0000 [V]
Data type: FloatingPoint32
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
6.0000 [V]
Data type: FloatingPoint32
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
100.0 [%]
Data type: Unsigned32
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
0000 bin
0 signal
No
No
No
No
Data type: FloatingPoint32
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
50.00 [%]
FP
-
-
-
-
475