Download Print this page

Function Diagrams - Siemens SINAMICS G120 List Manual

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

2 Parameters
2.1 Overview of parameters
2.1
Overview of parameters
2.1.1
Explanation of the parameter list
Basic structure of the parameter descriptions
The data in the following example have been chosen at random. The table below contains all
the information that can be included in a parameter description. Some of the information is
optional.
The "List of parameters (Page 25)" has the following structure:
- - - - - - - - - - - - Start of example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
pxxxx[0...n]
BICO: Full parameter name / abbreviated name
CU/PM variants
Access level: 3
Can be changed: C(x), U, T
Unit group: 6_2
Min
0.00 [Nm]
Description:
Text
Values:
0:
1:
2:
etc.
Recommendation:
Text
Index:
[0] = Name and meaning of index 0
[1] = Name and meaning of index 1
[2] = Name and meaning of index 2
etc.
Bit array:
Bit
00
01
02
Dependency:
Text
See also: pxxxx, rxxxx
See also: Fxxxxx, Axxxxx
Danger:
Warning:
Notice:
Note:
Information that might be useful.
- - - - - - - - - - - - End of example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
The individual pieces of information are described in detail below.
12
Name and meaning of value 0
Name and meaning of value 1
Name and meaning of value 2
Signal name
Name and meaning of bit 0
Name and meaning of bit 1
Name and meaning of bit 2
etc.
Caution:
Calculated: p0340 = 1
Scaling: p2002
Unit selection: p0505
Max
10.00 [Nm]
1 signal
Yes
Yes
Yes
Safety notices with a warning triangle
Safety notice without a warning triangle
Data type: FloatingPoint32
Dyn. index: CDS, p0170
Function diagram: 8070
Factory setting
0.00 [Nm]
0 signal
No
No
No
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
FP
8060
-
8052

Hide quick links:

Advertisement

loading