Download Print this page

Siemens SINAMICS G120 List Manual page 515

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

p8712[0...3]
CAN Receive Mapping for RPDO 3 / Mapping RPDO 3
CU250S_V_CAN
Access level: 3
Can be changed: C(3), T
Unit group: -
Min
0000 hex
Description:
Sets the mapping parameters for CANopen Receive Process Data Object 3 (RPDO 3).
Index:
[0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note:
Corresponds to the CANopen object 1602 hex.
Dummy mapping not supported.
The parameter can only be written online when the associated COB ID in p870x is set as invalid.
p8713[0...3]
CAN Receive Mapping for RPDO 4 / Mapping RPDO 4
CU250S_V_CAN
Access level: 3
Can be changed: C(3), T
Unit group: -
Min
0000 hex
Description:
Sets the mapping parameters for CANopen Receive Process Data Object 4 (RPDO 4).
Index:
[0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note:
Corresponds to the CANopen object 1603 hex.
Dummy mapping not supported.
The parameter can only be written online when the associated COB ID in p870x is set as invalid.
p8714[0...3]
CAN Receive Mapping for RPDO 5 / Mapping RPDO 5
CU250S_V_CAN
Access level: 3
Can be changed: C(3), T
Unit group: -
Min
0000 hex
Description:
Sets the mapping parameters for CANopen Receive Process Data Object 5 (RPDO 5).
Index:
[0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note:
Corresponds to the CANopen object 1604 hex.
Dummy mapping not supported.
The parameter can only be written online when the associated COB ID in p870x is set as invalid.
p8715[0...3]
CAN Receive Mapping for RPDO 6 / Mapping RPDO 6
CU250S_V_CAN
Access level: 3
Can be changed: C(3), T
Unit group: -
Min
0000 hex
Description:
Sets the mapping parameters for CANopen Receive Process Data Object 6 (RPDO 6).
Index:
[0] = Mapped object 1
[1] = Mapped object 2
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: -
Unit selection: -
Max
FFFF FFFF hex
Calculated: -
Scaling: -
Unit selection: -
Max
FFFF FFFF hex
Calculated: -
Scaling: -
Unit selection: -
Max
FFFF FFFF hex
Calculated: -
Scaling: -
Unit selection: -
Max
FFFF FFFF hex
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: 9204, 9206
Factory setting
0000 hex
Data type: Unsigned32
Dyn. index: -
Func. diagram: 9204, 9206
Factory setting
0000 hex
Data type: Unsigned32
Dyn. index: -
Func. diagram: 9204
Factory setting
0000 hex
Data type: Unsigned32
Dyn. index: -
Func. diagram: 9204
Factory setting
0000 hex
515