Induction motor and synchronous motor
Zero mark
Diag Gn_XIST1
Fine resolution
A,B
for speed actual
[0]
r0479
value
[4704.8]
Raw position
signals from
encoder 1
[4704.8]
1 encoder revolution
Zero mark
<1> Only for vector control without encoder.
<2>
Only for operation with encoder and PMSM.
<3>
For induction motors only (ASM).
1
2
Encoder evaluation
Speed actual value and pole pos. sensing, motor encoder ASM/PMSM (encoder 1)
Only for synchronous motor.
Pole position sensing
-1
n_act_measurement
Enc inv act value
p0410 [E]
0
up
dx
x
dt
-1
1
dn
III
0
-1
1
3
4
Enc inv act value
p0410 [E]
0
Transformat_angle [°]
r0094
<2>
1
n_act T_smooth
0.00 ... 50.00 [ms]
p1441 [D] (0.00)
Smoothing
ZSW n_ctrl
r1407
1 = Sensorless operation active
[2522.6]
r1407
.1
0
1
<1>
n_act calculation
[6730.3], [6841.3] <3>
[6731.3], [6842.3]
5
6
fp_4715_97_55.vsd
05.09.2017
n_act unsmoothed [rpm]
[6730.1], [6841.3] <3>
r0061
[0]
[6731.1], [6842.1]
Encoder angle
To basic braking control [2701.1]
To speed controller with/without encoder [6040.1]
To Kp_n-/Tn_n adaptation [6050.1]
Actual speed
To current/power/torque limits [6640.1]
[rpm]
To Iq and Id controllers [6714.7]
r0063
[0]
To field-weakening characteristic [6722.1], [6724.1]
To display signals [6799.1]
To speed signals 1 [8010.1]
Disp_val T_smooth
0.00 ... 10000.00 [ms]
p0045 (4.00)
Actual speed
[rpm]
r0063
[1]
7