Download Print this page

Siemens SINAMICS G120 List Manual page 79

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

r0370[0...n]
Motor stator resistance cold / Mot R_stator cold
Access level: 4
Can be changed: -
Unit group: -
Min
- [ohm]
Description:
Displays the motor stator resistance at an ambient temperature (p0625).
The value does not include the cable resistance.
Dependency:
Refer to: p0625
r0372[0...n]
Cable resistance / Mot R_cable
Access level: 4
Can be changed: -
Unit group: -
Min
- [ohm]
Description:
Displays the total cable resistance between power unit and motor, as well as the internal converter resistance.
Dependency:
Refer to: r0238, p0352
r0373[0...n]
Motor rated stator resistance / Mot R_stator rated
Access level: 4
Can be changed: -
Unit group: -
Min
- [ohm]
Description:
Displays the rated motor stator resistance at rated temperature (total of p0625 and p0627).
Dependency:
Refer to: p0627
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
r0374[0...n]
Motor rotor resistance cold / Mot R_r cold
Access level: 4
Can be changed: -
Unit group: -
Min
- [ohm]
Description:
Displays the motor rotor resistance at an ambient temperature p0625.
Dependency:
Refer to: p0625
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
r0376[0...n]
Rated motor rotor resistance / Mot rated R_rotor
Access level: 4
Can be changed: -
Unit group: -
Min
- [ohm]
Description:
Displays the nominal rotor resistance of the motor at the rated temperature.
The rated temperature is the sum of p0625 and p0628.
Dependency:
Refer to: p0628
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: -
Unit selection: -
Max
- [ohm]
Calculated: -
Scaling: -
Unit selection: -
Max
- [ohm]
Calculated: -
Scaling: -
Unit selection: -
Max
- [ohm]
Calculated: -
Scaling: -
Unit selection: -
Max
- [ohm]
Calculated: -
Scaling: -
Unit selection: -
Max
- [ohm]
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [ohm]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [ohm]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [ohm]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [ohm]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [ohm]
79