p2072
Response receive value after PZD failure / Resp aft PZD fail
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the response for the receive value (r2090) after PZD failure.
Bit field:
Bit
00
r2074[0...11]
PROFIdrive diagnostics bus address PZD receive / Diag addr recv
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the PROFIBUS address of the sender from which the process data (PZD) is received.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
Note:
Value range:
0 - 125: Bus address of the sender
65535: Not assigned
r2075[0...11]
PROFIdrive diagnostics telegram offset PZD receive / Diag offs recv
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the PZD byte offset in the PROFIdrive receive telegram (controller output).
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
Note:
Value range:
0 - 242: Byte offset
65535: Not assigned
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Signal name
Unconditionally open holding brake (p0855) Freeze value
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0000 bin
0 signal
Zero the value
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2410
Factory setting
-
FP
-
327