Download Print this page

Siemens SINAMICS G120 List Manual page 50

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

2 Parameters
2.2 List of parameters
Dependency:
For standard induction motors (p0301 > 10000), bit 0 is automatically pre-assigned the connection type of the
selected data set.
For p0100 > 0 (60 Hz rated motor frequency), it is not possible to select bit 1.
Refer to: p0304, p0305, p1082
Note:
For bit 00:
When changing the bits, the rated motor voltage p0304 and the rated motor current p0305 are automatically
converted to the selected connection type (star/delta).
For bit 01:
87 Hz operation is only possible in the delta connection type. When selected, the maximum speed p1082 is
automatically pre-assigned for a maximum output frequency of 87 Hz.
p0140
Number of Encoder Data Sets (EDS) / EDS count
Access level: 2
Can be changed: C(4)
Unit group: -
Min
2
Description:
Sets the number of Encoder Data Sets (EDS).
Note:
When parameterizing the drive with "no encoder" there must be at least one encoder data set (p0140 >= 1).
p0142[0...n]
Encoder component number / Encoder comp_no
Access level: 3
Can be changed: -
Unit group: -
Min
0
Description:
This parameter is used to assign the encoder data set to an encoder.
This assignment is made using the unique component number that was assigned when parameterizing the topology.
Only component numbers can be entered into this parameter that correspond to an encoder.
Note:
If the encoder evaluation and encoder are integrated (motor with DRIVE-CLiQ), then their component numbers are
identical.
For an SMC, different component numbers are assigned for the SMC (p0141) and the (actual) encoder (p0142).
r0148[0...n]
Sensor Module firmware version / SM FW version
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the firmware version of the Sensor Module.
Dependency:
Refer to: r0018, r0197, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
p0170
Number of Command Data Sets (CDS) / CDS count
Access level: 2
Can be changed: C(15)
Unit group: -
Min
2
Description:
Sets the number of Command Data Sets (CDS).
Dependency:
Refer to: p0010, r3996
Notice:
When the data sets are created, short-term communication interruptions may occur.
Note:
It is possible to toggle between command parameters (BICO parameters) using this data set changeover.
50
Calculated: -
Scaling: -
Unit selection: -
Max
2
Calculated: -
Scaling: -
Unit selection: -
Max
199
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
4
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
2
Data type: Unsigned8
Dyn. index: EDS, p0140
Func. diagram: 4704
Factory setting
0
Data type: Unsigned32
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
-
Data type: Unsigned8
Dyn. index: -
Func. diagram: 8560
Factory setting
2
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890

Hide quick links:

Advertisement

loading