2 Parameters
2.2 List of parameters
r0094
CO: Transformation angle / Transformat_angle
Access level: 3
Can be changed: -
Unit group: -
Min
- [°]
Description:
Displays the transformation angle.
Dependency:
Refer to: p0431, r1778
Note:
The transformation angle corresponds to the electrical commutation angle.
p0096
Application class / Appl_class
PM240
Access level: 1
Can be changed: C(1)
Unit group: -
Min
0
Description:
Setting the commissioning and control view for various application classes.
Value:
0:
1:
2:
Dependency:
The parameter is preset when commissioning the system for the first time and for the factory setting, depending on
the power unit that is connected.
Depending on the setting, the ability to see control parameters is restricted depending on the particular application.
The following applies for p0096 > 0:
The motor data identification routine is preset (p1900 = 12). After the motor data identification, the system
immediately goes into operation.
The following applies for p0096 = 1:
The motor type (p0300) synchronous or reluctance motor is not possible.
Note:
When changing p0096 to 1 or 2, when completing commissioning, fast parameterization should be executed (p3900
> 0).
Depending on the setting, after quick commissioning and/or automatic parameterization, the procedure for motor
data identification as well as the setting of the operating mode and parameterization of the closed-loop control must
be appropriately adapted.
p0100
IEC/NEMA mot stds / IEC/NEMA mot stds
Access level: 1
Can be changed: C(1)
Unit group: -
Min
0
Description:
Defines whether the motor and drive converter power settings (e.g. rated motor power, p0307) are expressed in [kW]
or [hp].
Depending on the selection, the rated motor frequency (p0310) is either set to 50 Hz or 60 Hz.
For p0100 = 0, 2, the following applies: The power factor (p0308) should be parameterized.
For p0100 = 1, the following applies: The efficiency (p0309) should be parameterized.
Value:
0:
1:
2:
Dependency:
If p0100 is changed, all of the rated motor parameters are reset. Only then are possible unit changeovers made.
The units of all motor parameters are changed that are involved in the selection of IEC or NEMA (e.g. r0206, p0307,
r0333, r0334, p0341, p0344, r1969).
Refer to: r0206, p0210, p0300, p0304, p0305, p0307, p0308, p0309, p0310, p0311, p0314, p0320, p0322, p0323,
p0335, r0337, p1800
Note:
The parameter value is not reset when the factory setting is restored (p0010 = 30, p0970).
48
Expert
Standard Drive Control (SDC)
Dynamic Drive Control (DDC)
IEC-Motor (50 Hz, SI units)
NEMA motor (60 Hz, US units)
NEMA motor (60 Hz, SI units)
Calculated: -
Scaling: p2005
Unit selection: -
Max
- [°]
Calculated: -
Scaling: -
Unit selection: -
Max
2
Calculated: -
Scaling: -
Unit selection: -
Max
2
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [°]
Data type: Integer16
Dyn. index: -
Func. diagram: 6019
Factory setting
0
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890