2 Parameters
2.2 List of parameters
p0428[0...n]
Encoder SSI monoflop time / Enc SSI t_monoflop
Access level: 3
Can be changed: C(4)
Unit group: -
Min
0 [µs]
Description:
Sets the minimum delay time between two data transfers of the absolute value for an SSI encoder.
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
p0429[0...n]
Encoder SSI configuration / Enc SSI config
Access level: 3
Can be changed: C(4)
Unit group: -
Min
-
Description:
Sets the configuration for an SSI encoder.
Bit field:
Bit
00
02
06
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
For bit 06:
The quiescent signal level of the data line corresponds to the inverted, set level.
p0430[0...n]
Sensor Module configuration / SM config
Access level: 3
Can be changed: C(4)
Unit group: -
Min
-
Description:
Sets the configuration of the Sensor Module.
Bit field:
Bit
17
18
19
20
21
22
23
24
25
27
28
29
30
31
Notice:
A bit-wise configuration is only possible if the corresponding property is also present in r0458.
90
Signal name
Transfer code
Transfer absolute value twice
Data line during the monoflop time
Signal name
Burst oversampling
Continuous oversampling (reserved)
Safety position actual value sensing
Speed calculation mode (only SMC30)
Zero mark tolerance
Rotor position adaptation
De-select commutation with zero mark
Commutation with selected zero mark
Switch off encoder voltage supply during
parking
Extrapolate position values
Cubic correction
Phase correction
Amplitude correction
Offset correction
Calculated: -
Scaling: -
Unit selection: -
Max
65535 [µs]
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Binary code
Yes
High level
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Incremental diff
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Data type: Unsigned16
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
30 [µs]
Data type: Unsigned16
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
0000 0000 bin
0 signal
Gray code
No
Low level
Data type: Unsigned32
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
1110 0000 0000 1000 0000 0000 0000
0000 bin
0 signal
No
No
No
Flank time meas
No
No
No
No
No
No
No
No
No
No
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890