p0180
Number of Drive Data Sets (DDS) / DDS count
Access level: 3
Can be changed: C(15)
Unit group: -
Min
1
Description:
Sets the number of Drive Data Sets (DDS).
Dependency:
Refer to: p0010, r3996
Notice:
When the data sets are created, short-term communication interruptions may occur.
p0187[0...n]
Encoder 1 encoder data set number / Enc 1 EDS number
Access level: 3
Can be changed: C(4)
Unit group: -
Min
0
Description:
Assign a drive data set (= index) the corresponding encoder data set (EDS) for encoder 1.
The value corresponds to the number of the assigned encoder data set.
Example:
Encoder 1 in drive data set 2 should be assigned encoder data set 0.
--> p0187[2] = 0
Note:
A value of 99 means that no encoder has been assigned to this drive data set (not configured).
p0188[0...n]
Encoder 2 encoder data set number / Enc 2 EDS number
Access level: 3
Can be changed: C(4)
Unit group: -
Min
0
Description:
Assign a drive data set (= index) the corresponding encoder data set (EDS) for encoder 2.
The value corresponds to the number of the assigned encoder data set.
Example:
Encoder 2 in drive data set 2 should be assigned to encoder data set 1.
--> p0188[2] = 1
Note:
A value of 99 means that no encoder has been assigned to this drive data set (not configured).
r0197[0...1]
Bootloader version / Bootloader vers
Access level: 4
Can be changed: -
Unit group: -
Min
-
Description:
Displays the bootloader version.
Index 0:
Displays the bootloader version.
Index 1:
Displays the bootloader version 3 (for CU320-2 and CU310-2)
Value 0 means that boot loader 3 is not available.
Dependency:
Refer to: r0018, r0148, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: -
Unit selection: -
Max
4
Calculated: -
Scaling: -
Unit selection: -
Max
99
Calculated: -
Scaling: -
Unit selection: -
Max
99
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Unsigned8
Dyn. index: -
Func. diagram: 8565
Factory setting
1
Data type: Unsigned8
Dyn. index: DDS, p0180
Func. diagram: 8570
Factory setting
0
Data type: Unsigned8
Dyn. index: DDS, p0180
Func. diagram: 8570
Factory setting
1
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
51