Download Print this page

Siemens SINAMICS G120 List Manual page 581

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

r9773.0...31
CO/BO: SI status (processor 1 + processor 2) / SI status P1+P2
Access level: 2
Can be changed: -
Unit group: -
Min
-
Description:
Display and BICO output for the Safety Integrated status on the drive (processor 1 + processor 2).
Bit field:
Bit
00
01
02
04
05
06
30
31
Note:
This status is formed from the AND operation of the relevant status of the two monitoring channels.
r9776
SI diagnostics / SI diag
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
The parameter is used for diagnostics.
Bit field:
Bit
00
01
02
03
Note:
For bit 00 = 1:
At least one Safety parameter has been changed that will only take effect after a POWER ON.
For bit 01 = 1:
Safety functions (basic functions or extended functions) have been enabled and are active.
For bit 02 = 1:
A safety-relevant component has been replaced. Data save required (p0977 = 1 or p0971 = 1 or "copy RAM to
ROM").
For bit 03 = 1:
A safety-relevant component has been replaced. Acknowledge (p9702 = 29) and save (p0977 = 1 or p0971 = 1 or
"Copy RAM to ROM") required.
r9780
SI monitoring clock cycle (processor 1) / SI mon_clk cyc P1
Access level: 3
Can be changed: -
Unit group: -
Min
- [ms]
Description:
Displays the clock cycle time for the Safety Integrated Basic Functions on processor 1.
Note:
Information regarding the relationship between monitoring clock cycle and response times can be found in the
following references:
- SINAMICS G120 Function Manual Safety Integrated
- technical documentation for the particular product
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Signal name
STO selected in drive
STO active in drive
SS1 delay time active in the drive
SBC requested
SS1 selected in the drive (Basic Functions)
SS1 active in the drive (Basic Functions)
Test stop required for STO via PM terminals Yes
Test stop required for STO
Signal name
Safety parameter changed POWER ON
required
Safety functions enabled
Safety component replaced and data save
required
Safety component replaced and
acknowledge/save required
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
- [ms]
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2804
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2802
Factory setting
- [ms]
FP
2804
2804
2804
2804
-
-
-
2810
FP
-
-
-
-
581

Hide quick links:

Advertisement