r2522[0...3]
CO: LR velocity actual value / v_act
CU250S_V (Position
Access level: 1
control)
Can be changed: -
CU250S_V_CAN
Unit group: -
(Position control)
Min
CU250S_V_DP
- [1000 LU/min]
(Position control)
CU250S_V_PN
(Position control)
Description:
Display and connector output for the actual position actual value determined by the velocity actual value
preprocessing.
Index:
[0] = Position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency:
Refer to: p2502, r2526
Note:
r2526.0 = 1 --> The velocity actual value in r2522[0] for the position control is valid.
r2527.0 = 1 --> The velocity actual value in r2522[1] for encoder 1 is valid.
r2528.0 = 1 --> The velocity actual value in r2522[2] for encoder 2 is valid.
r2523[0...3]
CO: LR measured value / Measured value
CU250S_V (Position
Access level: 1
control)
Can be changed: -
CU250S_V_CAN
Unit group: -
(Position control)
Min
CU250S_V_DP
- [LU]
(Position control)
CU250S_V_PN
(Position control)
Description:
Display and connector output for the value determined by the function "reference mark search" and "measuring
probe evaluation".
Index:
[0] = Position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency:
Refer to: p2502, r2526
Note:
r2526.2 = 1 --> The measured value in r2523[0] for the position control is valid.
r2527.2 = 1 --> The measured value in r2523[1] for encoder 1 is valid.
r2528.2 = 1 --> The measured value in r2523[2] for encoder 2 is valid.
r2524
CO: LR LU/revolution / LU/revolution
CU250S_V (Position
Access level: 1
control)
Can be changed: -
CU250S_V_CAN
Unit group: -
(Position control)
Min
CU250S_V_DP
- [LU]
(Position control)
CU250S_V_PN
(Position control)
Description:
Display and connector output for the internal length units LU/motor revolution.
Dependency:
Refer to: p0404
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: -
Unit selection: -
Max
- [1000 LU/min]
Calculated: -
Scaling: -
Unit selection: -
Max
- [LU]
Calculated: -
Scaling: -
Unit selection: -
Max
- [LU]
2 Parameters
2.2 List of parameters
Data type: Integer32
Dyn. index: -
Func. diagram: 4010
Factory setting
- [1000 LU/min]
Data type: Integer32
Dyn. index: -
Func. diagram: 4010
Factory setting
- [LU]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 3630, 4010
Factory setting
- [LU]