p0922
PROFIdrive PZD telegram selection / PZD telegr_sel
CU250S_V_DP
Access level: 1
CU250S_V_PN
Can be changed: C(1), T
Unit group: -
Min
1
Description:
Sets the send and receive telegram.
Value:
1:
2:
3:
4:
20:
350:
352:
353:
354:
999:
Dependency:
Refer to: F01505
Note:
For p0922 = 100 ... 199, p2038 is automatically set to 1 and p2038 can no longer be changed. This means that for
these telegrams, the "SIMODRIVE 611 universal" interface mode is set and cannot be changed.
If a value is not equal to 999, a telegram is set and the automatically set interconnections in the telegram are
inhibited.
The inhibited interconnections can only be changed again after setting value 999.
p0922
PROFIdrive PZD telegram selection / PZD telegr_sel
CU250S_V_DP
Access level: 1
(EPOS)
Can be changed: C(1), T
CU250S_V_PN
Unit group: -
(EPOS)
Min
7
Description:
Sets the send and receive telegram.
Value:
7:
9:
110:
111:
999:
Dependency:
Refer to: F01505
Note:
For p0922 = 100 ... 199, p2038 is automatically set to 1 and p2038 can no longer be changed. This means that for
these telegrams, the "SIMODRIVE 611 universal" interface mode is set and cannot be changed.
If a value is not equal to 999, a telegram is set and the automatically set interconnections in the telegram are
inhibited.
The inhibited interconnections can only be changed again after setting value 999.
p0925
PROFIdrive clock synchronous sign-of-life tolerance / PD SoL_tol
Access level: 3
Can be changed: U, T
Unit group: -
Min
0
Description:
Sets the number of tolerated consecutive sign-of-life errors of the isochronous master.
The sign-of-life signal is normally received in PZD4 (control word 2) from the master.
Dependency:
Refer to: p2045, r2065
Refer to: F01912
Note:
The sign-of-life monitoring is disabled for p0925 = 65535.
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Standard telegram 1, PZD-2/2
Standard telegram 2, PZD-4/4
Standard telegram 3, PZD-5/9
Standard telegram 4, PZD-6/14
Standard telegram 20, PZD-2/6
SIEMENS telegram 350, PZD-4/4
SIEMENS telegram 352, PZD-6/6
SIEMENS telegram 353, PZD-2/2, PKW-4/4
SIEMENS telegram 354, PZD-6/6, PKW-4/4
Free telegram configuration with BICO
Standard telegram 7, PZD-2/2
Standard telegram 9, PZD-10/5
SIEMENS telegram 110, PZD-12/7
SIEMENS telegram 111, PZD-12/12
Free telegram configuration with BICO
Calculated: -
Scaling: -
Unit selection: -
Max
999
Calculated: -
Scaling: -
Unit selection: -
Max
999
Calculated: -
Scaling: -
Unit selection: -
Max
65535
2 Parameters
2.2 List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2401, 2421, 2422
Factory setting
1
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2401, 2421, 2422
Factory setting
999
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2410
Factory setting
1
171