Download Print this page

Siemens SINAMICS G120 List Manual page 421

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

p2624
EPOS traversing block sorting / Trav_block sort
CU250S_V (EPOS)
Access level: 1
CU250S_V_CAN
Can be changed: U, T
(EPOS)
Unit group: -
CU250S_V_DP
Min
(EPOS)
0
CU250S_V_PN
(EPOS)
Description:
Sets the traversing blocks for sorting corresponding to their block number.
Procedure: Set p2624 = 0 --> 1.
Sorting is started and the parameters are automatically reset to zero once the operation has been completed.
Dependency:
Refer to: p2615, p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2623
Note:
After sorting, the traversing blocks are written at the beginning of the memory in increasing sequence without any
gaps.
p2625
BI: EPOS traversing block selection bit 0 / Trav_blk sel bit 0
CU250S_V (EPOS)
Access level: 1
CU250S_V_CAN
Can be changed: T
(EPOS)
Unit group: -
CU250S_V_DP
Min
(EPOS)
-
CU250S_V_PN
(EPOS)
Description:
Sets the signal source to select the traversing block, bit 0.
Dependency:
Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2626, p2627, p2628
p2626
BI: EPOS traversing block selection bit 1 / Trav_blk sel bit 1
CU250S_V (EPOS)
Access level: 1
CU250S_V_CAN
Can be changed: T
(EPOS)
Unit group: -
CU250S_V_DP
Min
(EPOS)
-
CU250S_V_PN
(EPOS)
Description:
Sets the signal source to select the traversing block, bit 1.
Dependency:
Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2627, p2628
p2627
BI: EPOS traversing block selection bit 2 / Trav_blk sel bit 2
CU250S_V (EPOS)
Access level: 1
CU250S_V_CAN
Can be changed: T
(EPOS)
Unit group: -
CU250S_V_DP
Min
(EPOS)
-
CU250S_V_PN
(EPOS)
Description:
Sets the signal source to select the traversing block, bit 2.
Dependency:
Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2626, p2628
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: -
Unit selection: -
Max
1
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: 3616
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3616, 3640
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3616, 3640
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3616, 3640
Factory setting
0
421

Hide quick links:

Advertisement

loading