Download Print this page

Siemens SINAMICS G120 List Manual page 263

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

p1514[0...n]
Supplementary torque 2 scaling / M_suppl 2 scal
Access level: 3
Can be changed: U, T
Unit group: -
Min
-2000.0 [%]
Description:
Sets the scaling for supplementary torque 2.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
r1515
Supplementary torque total / M_suppl total
Access level: 2
Can be changed: -
Unit group: 7_1
Min
- [Nm]
Description:
Displays the total supplementary torque.
The displayed value is the total of supplementary torque values 1 and 2 (p1511, p1512, p1513, p1514).
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
r1516
CO: Supplementary torque and acceleration torque / M_suppl + M_accel
Access level: 2
Can be changed: -
Unit group: 7_1
Min
- [Nm]
Description:
Displays the total supplementary torque and the accelerating torque.
The displayed value is the total of the smoothed supplementary torque and the accelerating torque (p1516 =
p1518[1] + r1515).
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1517[0...n]
Accelerating torque smoothing time constant / M_accel T_smooth
Access level: 3
Can be changed: U, T
Unit group: -
Min
0.00 [ms]
Description:
Sets the smoothing time constant of the accelerating torque.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note:
The acceleration precontrol is inhibited if the smoothing is set to the maximum value.
r1518[0...1]
CO: Accelerating torque / M_accel
Access level: 3
Can be changed: -
Unit group: 7_1
Min
- [Nm]
Description:
Displays the accelerating torque for precontrol of the speed controller.
Index:
[0] = Unsmoothed
[1] = Smoothed
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p0341, p0342, p1496
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
2000.0 [%]
Calculated: -
Scaling: p2003
Unit selection: p0505
Max
- [Nm]
Calculated: -
Scaling: p2003
Unit selection: p0505
Max
- [Nm]
Calculated: -
Scaling: -
Unit selection: -
Max
100.00 [ms]
Calculated: -
Scaling: p2003
Unit selection: p0505
Max
- [Nm]
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6020, 6060
Factory setting
100.0 [%]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6020, 6060
Factory setting
- [Nm]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6060
Factory setting
- [Nm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6060
Factory setting
4.00 [ms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6060
Factory setting
- [Nm]
263