r2146[0...63]
Alarm time removed in days / t_alarm res days
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the system runtime in days when the alarm was cleared.
Dependency:
Refer to: r2110, r2122, r2123, r2124, r2125, r2134, r2145
Notice:
The time comprises r2146 (days) and r2125 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
p2148[0...n]
BI: RFG active / RFG active
Access level: 3
Can be changed: U, T
Unit group: -
Min
-
Description:
Sets the signal source for the signal "ramp-function generator active" for the following signals/messages:
"Speed setpoint - actual value deviation within tolerance t_on" (BO: r2199.4)
"Ramp-up/ramp-down completed" (BO: r2199.5)
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
The binector input is automatically interconnected to r1199.2 as a default setting.
p2149[0...n]
Monitoring configuration / Monit config
Access level: 3
Can be changed: U, T
Unit group: -
Min
-
Description:
Sets the configuration for messages and monitoring functions.
Bit field:
Bit
00
01
03
05
Dependency:
Refer to: r2197
Refer to: A07903
Note:
For bit 00:
Alarm A07903 is output when the bit is set with r2197.7 = 0 (n_set <> n_act).
For bit 01:
When the bit is set, the load monitoring is only executed in the 1st quadrant as a result of the positive characteristic
parameters (p2182 ... p2190).
For bit 03:
When the bit is set, r2197.1 and r2197.2 are determined using separate hysteresis functions.
For bit 05:
When this bit is set, a change to open-loop speed controlled operation is only possible when the motor is stationary.
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Signal name
Enable alarm A07903
Load monitoring only in the 1st quadrant
n_act > p2155 own hysteresis
Stall monitoring for encoderless speed
control
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: p0340 = 1,3,5
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: 8065
Factory setting
-
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 8011
Factory setting
0
Data type: Unsigned16
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
0000 1001 bin
0 signal
No
No
No
No
FP
8011
8013
8010
-
349