Download Print this page

Siemens SINAMICS G120 List Manual page 417

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

Dependency:
Refer to: p2609
p2611
EPOS search for reference approach velocity reference point / v_appr ref_pt
CU250S_V (EPOS)
Access level: 1
CU250S_V_CAN
Can be changed: U, T
(EPOS)
Unit group: -
CU250S_V_DP
Min
(EPOS)
1 [1000 LU/min]
CU250S_V_PN
(EPOS)
Description:
Sets the approach velocity after detecting the zero mark to approach the reference point.
Dependency:
Refer to: p2595, p2597, p2604, p2607, p2609, p2610
Note:
When traversing to the reference point, the velocity override is not effective.
p2612
BI: EPOS search for reference reference cam / Ref_cam
CU250S_V (EPOS)
Access level: 1
CU250S_V_CAN
Can be changed: T
(EPOS)
Unit group: -
CU250S_V_DP
Min
(EPOS)
-
CU250S_V_PN
(EPOS)
Description:
Sets the signal source for the reference cam.
Dependency:
Refer to: p2607
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2613
BI: EPOS search for reference reversing cam minus / Rev minus
CU250S_V (EPOS)
Access level: 1
CU250S_V_CAN
Can be changed: T
(EPOS)
Unit group: -
CU250S_V_DP
Min
(EPOS)
-
CU250S_V_PN
(EPOS)
Description:
Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency:
Refer to: p2614
Note:
If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
p2614
BI: EPOS search for reference reversing cam plus / Rev plus
CU250S_V (EPOS)
Access level: 1
CU250S_V_CAN
Can be changed: T
(EPOS)
Unit group: -
CU250S_V_DP
Min
(EPOS)
-
CU250S_V_PN
(EPOS)
Description:
Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency:
Refer to: p2613
Note:
If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: -
Unit selection: -
Max
40000000 [1000 LU/min]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: 3612
Factory setting
300 [1000 LU/min]
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3612
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3612
Factory setting
1
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3612
Factory setting
1
417

Hide quick links:

Advertisement

loading