Siemens SINAMICS G120 List Manual page 584

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

2 Parameters
2.2 List of parameters
r9795
SI diagnostics STOP F (processor 1) / SI diag STOP F P1
Access level: 2
Can be changed: -
Unit group: -
Min
-
Description:
Displays the number of the cross-checked data item which caused STOP F on processor 1.
Dependency:
Refer to: F01611
Note:
A complete list of numbers for cross-checked data items appears in fault F01611.
r9798
SI actual checksum SI parameters (processor 1) / SI act chksm P1
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the checksum for the Safety Integrated parameters checked using checksums on processor 1 (actual
checksum).
Dependency:
Refer to: p9799, r9898
p9799
SI reference checksum SI parameters (processor 1) / SI setp_chksm P1
Access level: 3
Can be changed: C(95)
Unit group: -
Min
0000 hex
Description:
Sets the checksum for the Safety Integrated parameters checked using checksums on processor 1 (reference
checksum).
Dependency:
Refer to: r9798, p9899
p9801
SI enable functions integrated in the drive (processor 2) / SI enable fct P2
CU250S_V_DP
Access level: 3
CU250S_V_PN
Can be changed: C(95)
Unit group: -
Min
-
Description:
Sets the enable signals for the safety functions integrated in the drive and the type of selection on processor 2.
Not all of the settings listed below will be permissible, depending on the Control Unit and Power Module being used:
0000 hex:
Safety functions integrated in the drive inhibited (no safety function).
0001 hex:
Basic functions are enabled via onboard terminals (permissible for r9771.0 = 1).
0004 hex:
Extended functions are enabled via onboard terminals (permissible for r9771.5 = 1).
0008 hex:
Basic functions are enabled via PROFIsafe (permissible for r9771.6 = 1).
0009 hex:
Basic functions are enabled via PROFIsafe onboard terminals (permissible for r9771.6 = 1).
000C hex:
Extended functions are enabled via PROFIsafe (permissible for r9771.4 = 1).
584
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
FFFF FFFF hex
Calculated: -
Scaling: -
Unit selection: -
Max
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2802
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2800
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2800
Factory setting
0000 hex
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
0000 0000 bin
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890