Sending Trap Messages When Probes Failed - Huawei S9300 Configuration Manual

Table of Contents

Advertisement

S9300&S9300E Terabit Routing Switch
Configuration Guide - Network Management
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
test-type { jitter | icmpjitter }
The test type is configured.
Step 4 Run:
destination-address ipv4 ip-address
The destination IP address is configured.
Step 5 (Optional)Run:
destination-port port-number
The destination port number is configured.
Step 6 Run:
send-trap testfailure
Sending trap messages when tests fail is enabled.
By default, the trap function is disabled.
Step 7 Run:
test-failtimes times
The number of test failures that trigger sending a trap message is configured.
By default, a trap message is sent for each test failure.
----End

6.31.3 Sending Trap Messages When Probes Failed

A trap message is sent to the NMS when the NQA test fails.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
test-type tcp
The test type is configured.
Step 4 Run:
destination-address ipv4 ip-address
Issue 01 (2012-03-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 NQA Configuration