Maintaining Nqa; Restarting Nqa Test Instances; Clearing Nqa Statistics - Huawei S9300 Configuration Manual

Table of Contents

Advertisement

S9300&S9300E Terabit Routing Switch
Configuration Guide - Network Management
<Quidway> display nqa-agent
NQA Tests Max:2000
NQA Flow
nqa test-instance admin icmp
test-type icmp
destination-address ipv4 11.1.1.32
frequency 5
alarm 10 rtt-average 2 rising-threshold 200 10 falling-threshold 0 10
alarm 20 lost-packet-ratio 2 rising-threshold 10 10 falling-threshold 1 10
nqa status : normal

6.34 Maintaining NQA

This section describes how to maintain an NQA test instance. You can restart the test instance
and clear the statistics on the test result to maintain a test instance.

6.34.1 Restarting NQA Test Instances

If a test instance fails, you can try to restart the test instance in the next test period.
Prerequisites
To restart an NQA test instance, run the following command in the NQA instance view.
Context
Restarting an NQA test instance interrupts the running of tests.
Procedure
Step 1 Run the system-view command, enter the system view.
Step 2 Run the nqa test-instance admin-name test-name command, enter the NQA test instance view.
Step 3 Run the restart command in the NQA instance view to restart an NQA test instance.
----End

6.34.2 Clearing NQA Statistics

When the statistics on the current test instance are saved to the FTP server, you can clear test
results on the device.
Prerequisites
NQA statistics cannot be restored after you clear them. So, confirm the action before you use
the command.
Issue 01 (2012-03-15)
Max:1000
CAUTION
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
NQA Tests
Number:
NQA Flow Remained:1000
6 NQA Configuration
1
381

Advertisement

Table of Contents
loading

This manual is also suitable for:

S9300e

Table of Contents