6.35.7 Example for Configuring the SNMP Query Test

Networking Requirements
As shown in
used to measure the time from sending an SNMP query packet to receiving an Echo packet.
Figure 6-9 Networking diagram for configuring the SNMP query test
SwitchA
Configuration Roadmap
The configuration roadmap is as follows:
1.
2.
3.
Data Preparation
To complete the configuration, you need the following data:
l
Procedure
Step 1 Configure reachable routes between Switch A and Switch B, between Switch A and Switch C,
and between Switch B and Switch C. The configuration details are not mentioned here.
Step 2 Enable SNMP agent on Switch C.
<SwitchC> system-view
[SwitchC] snmp-agent
Issue 01 (2012-03-15)
#
sysname SwitchC
#
vlan batch 110
#
interface Vlanif110
ip address 10.2.1.2 255.255.255.0
#
interface GigabitEthernet1/0/0
port hybrid pvid vlan 110
port hybrid untagged vlan 110
#
ip route-static 10.1.1.0 255.255.255.0 10.2.1.1
#
return
Figure
6-9, SNMP agent is enabled on Switch C. The NQA SNMP query test is
GE1/0/0
GE1/0/0
VLANIF100
VLANIF100
10.1.1.1/24
10.1.1.2/24
Configure Switch A as the NQA client.
Create and perform the SNMP query test on Switch A.
Enable SNMP agent on Switch C.
Host address of the SNMP agent
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
SwitchB
GE2/0/0
VLANIF110
VLANIF110
10.2.1.1/24
10.2.1.2/24
6 NQA Configuration
SwitchC
GE1/0/0
SNMP Agent