Configuring Parameters For The Pwe3 Ping Test On A One-Hop Pw - Huawei S9300 Configuration Manual

Table of Contents

Advertisement

S9300&S9300E Terabit Routing Switch
Configuration Guide - Network Management
Data Preparation
To configure the PWE3 Ping test on a one-hop PW, you need the following data.
No.
1
2
3
4
5
6
6.24.2 Configuring Parameters for the PWE3 Ping Test on a One-
Hop PW
This part describes how to set PWE3 ping test parameters for a single-hop PW.
Context
Do as follows on the NQA client:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
test-type pwe3ping
The test type is set to PWE3 Ping.
Step 4 (Optional) Run:
vc-type ldp
The method of setting up a PW is configured.
Step 5 (Optional) Run:
local-pw-type { local-pw-type | ip-interworking }
The type of the local PW is configured. By default, the type is Ethernet.
Issue 01 (2012-03-15)
Data
ID of the PW
Type of the PW
Type and number of the interface connected with the CE
Destination IP address and ID of the L2VC
(Optional) Response mode of the Echo-Request packets, LSP EXP, maximum hops,
number of probes, TTL value, and timeout period of the packets
Start mode and end mode of the test
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 NQA Configuration
342