Configuring The Lsp Ping Test Parameters For The Cr-Lsp Hotstandby Tunnel - Huawei S9300 Configuration Manual

Table of Contents

Advertisement

S9300&S9300E Terabit Routing Switch
Configuration Guide - Network Management
Select the start mode as required because the start command has several forms.
l To perform the NQA test immediately, run the start now [ end { at [ yyyy/mm/dd ]
l To perform the NQA test at the specified time, run the start at [ yyyy/mm/dd ] hh:mm:ss
l To perform the NQA test after a certain delay period, run the start delay { seconds second
----End
6.16.4 Configuring the LSP Ping Test Parameters for the CR-LSP
Hotstandby Tunnel
Before performing the LSP ping test, you need set LSP ping test parameters for CR-LSP tunnels
in hot standby mode.
Context
Do as follows on the NQA client:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
test-type lspping
The test type is set to be LSP Ping.
Step 4 Run:
lsp-type te
The tunnel type is set to be TE tunnel.
Step 5 Run:
lsp-tetunnel tunnel interface-number hot-standby
The TE tunnel interface to be pinged is specified and the CR-LSP hotstandby tunnel is set to be
tested.
Issue 01 (2012-03-15)
hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime { seconds second | hh:mm:ss } ]
command.
The test instance is started immediately.
[ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime
{ seconds second | hh:mm:ss } ] command.
The test instance is started at a specified time.
| hh:mm:ss } [ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } |
lifetime { seconds second | hh:mm:ss } ] command.
The test instance is started after a certain delay.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 NQA Configuration
302

Advertisement

Table of Contents
loading

This manual is also suitable for:

S9300e

Table of Contents