Huawei S9300 Configuration Manual page 258

Table of Contents

Advertisement

S9300&S9300E Terabit Routing Switch
Configuration Guide - Network Management
After the configurations, the clock on Switch D can be synchronized to the clock on Switch C,
but the clock on Switch A cannot be synchronized
because Switch A and Switch C are on different network segments and Switch A cannot receive
the broadcast packets sent from Switch C.
Check the NTP status of Switch D, and you can see that the status of the clock is synchronized.
This means that the synchronization is complete. The stratum of the clock of Switch D is 4, one
stratum lower than the clock stratum of Switch C.
[SwitchD] display ntp-service status
clock status: synchronized
clock stratum: 4
reference clock ID: 3.0.1.31
nominal frequency: 60.0002 Hz
actual frequency: 60.0002 Hz
clock precision: 2^18
clock offset: 0.0000 ms
root delay: 0.00 ms
root dispersion: 0.42 ms
peer dispersion: 0.00 ms
reference time: 12:17:21.773 UTC Mar 7 2006(C7B7F851.C5EAF25B)
----End
Configuration Files
l
Issue 01 (2012-03-15)
Configuration file of Switch A
#
sysname SwitchA
#
vlan batch 20
#
interface Vlanif20
ip address 1.0.1.11 255.255.255.0
ntp-service broadcast-client
#
interface GigabitEthernet1/0/0
port hybrid pvid vlan 20
port hybrid untagged vlan 20
#
ospf 1
area 0.0.0.0
network 1.0.1.0 0.0.0.255
#
ntp-service authentication enable
ntp-service authentication-keyid 16 authentication-mode md5 %@ENC;8HX
\#Q=^Q`MAF4<1!!
ntp-service reliable authentication-keyid 16
#
return
Configuration file of Switch C
#
sysname SwitchC
#
vlan batch 10
#
interface Vlanif10
ip address 3.0.1.31 255.255.255.0
ntp-service broadcast-server authentication-keyid 16
#
interface GigabitEthernet1/0/0
port hybrid pvid vlan 10
port hybrid untagged vlan 10
#
ntp-service authentication enable
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 NTP Configuration
243