Huawei S9300 Configuration Manual page 223

Table of Contents

Advertisement

S9300&S9300E Terabit Routing Switch
Configuration Guide - Network Management
SNMP host:3.0.0.1
FTP server:2.0.0.1
SFTP server:2.0.0.2
cluster-member ftp-timeout: 300 second(s)(default)
Cluster SNMP NAT capability : enabled
Cluster FTP NAT capability : enabled
There are 4 member(s) in the cluster, and 0 of them are down.
Step 10 Disable NDP and NTDP.
# Disable NDP and NTDP on interfaces of all the member switches that do not need NDP and
NTDP.
# Disable NDP on the unrelated interfaces of member switches
[HUAWEI_0.Administrator-1] cluster
[HUAWEI_0.Administrator-1-cluster] undo cluster-member unrelated-port ndp
# Disable NTDP on the unrelated interfaces of member switches
[HUAWEI_0.Administrator-1] cluster
[HUAWEI_0.Administrator-1-cluster] undo cluster-member unrelated-port ntdp
Step 11 Verify the configuration.
After the previous configuration, run the display member-interface-state command on
administrator switch to check whether NDP or NTDP is disabled on unrelated interfaces of the
member switches, and you can view that success is displayed.
[HUAWEI_0.Administrator-1] display member-interface-state ndp
The result of member switches executed disable member interface command:
------------------------------------------------------------------------------
SN
------------------------------------------------------------------------------
3
2
1
[HUAWEI_0.Administrator-1] display member-interface-state ntdp
The result of member switches executed disable member interface command:
------------------------------------------------------------------------------
SN
------------------------------------------------------------------------------
------------------------------------------------------------------------------
------------------------------------------------------------------------------
3
2
1
----End
Configuration Files
l
Issue 01 (2012-03-15)
Device
S9300
S9300
S9300
Device
S9300&S9300E
S9300&S9300E
S9300&S9300E
Configuration file of Administrator-1.
#
sysname Administrator-1
#
vlan batch 10
#
cluster enable
ntdp enable
ntdp hop 3
ntdp timer 10
ndp enable
#
interface Vlanif10
ip address 1.0.0.1 255.0.0.0
#
interface GigabitEthernet1/0/1
port link-type trunk
port trunk allow-pass vlan 10
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
MacAddress
IpAddress
0004-0004-0004
10.0.0.4
0003-0003-0003
10.0.0.3
0002-0002-0002
10.0.0.2
MacAddress
IpAddress
0004-0004-0004
0003-0003-0003
0002-0002-0002
3 HGMP Configuration
result
success
success
success
result
10.0.0.4
success
10.0.0.3
success
10.0.0.2
success
208