S9300&S9300E Terabit Routing Switch
Configuration Guide - Network Management
6.35.14 Example for Configuring the LSP Jitter Test for the MPLS
TE Tunnel
This part provides examples for configuring an LSP jitter test to measure jitter in the TE LSP
during the packet transmission.
Networking Requirements
As shown in
l
l
l
It is required to perform an NQA LSP Jitter test to check the connectivity of the TE tunnel from
Switch A to Switch C.
Issue 01 (2012-03-15)
#
sysname SwitchC
#
vlan batch 100
#
mpls lsr-id 1.1.1.9
mpls
#
mpls ldp
#
interface Vlanif110
ip address 10.2.1.2 255.255.255.0
mpls
mpls ldp
#
interface
GigabitEthernet1/0/0
port hybrid pvid vlan 110
port hybrid untagged vlan 110
#
interface LoopBack1
ip address 3.3.3.9 255.255.255.255
#
ospf 1
area 0.0.0.0
network 3.3.3.9 0.0.0.0
network 10.2.1.0 0.0.0.255
#
return
Figure
6-16,
Run OSPF on Switch A, Switch B, and Switch C, and enable the three Switchs to advertise
host routes of loopback interfaces to each other.
Enable MPLS, MPLS TE, and MPLS RSVP-TE on Switch A, Switch B, and Switch C.
Enable MPLS, MPLS TE, and MPLS RSVP-TE on the VLANIF interfaces connecting
Switch A, Switch B and Switch C to set up a TE tunnel from Switch A and Switch C.