Step 1 Run the display nqa-agent [ admin-name test-name ] [ verbose ] to view the status of the test
instance configured on the NQA client.
----End
Example
Using the display nqa-agent [ admin-name test-name ] [ verbose ] command, you can view the
uni-directional transmission delay threshold configured for the NQA test. For example:
<Quidway> display nqa-agent verbose
NQA Tests Max:2000
NQA Flow
nqa test-instance admin jitter
test-type jitter
destination-address ipv4 100.1.1.201
destination-port 80
send-trap probefailure
send-trap testfailure
send-trap testcomplete
send-trap rtd
send-trap owd-sd
send-trap owd-ds
threshold owd-sd 2000
threshold owd-ds 2000
nqa status : normal

6.31 Configuring the Trap Function

This section describes how to configure the trap function in an NQA test instance. After the trap
function is configured, a trap message is sent to the NMS in case of transmission success or
transmission failure.

6.31.1 Establishing the Configuration Task

Before configuring the trap function, familiarize yourself with the applicable environment,
complete the pre-configuration tasks, and obtain the required data. This can help you complete
the configuration task quickly and accurately.
Applicable Environment
Trap messages are generated regardless of whether the NQA test is successful or fails. You can
control whether to send trap messages to the NM station by enabling or disabling the trap
function.
NQA supports three types of trap messages as defined in the DISMAN-PING-MIB.
l
l
Issue 01 (2012-03-15)
Max:1000
Trap message sent when an NQA probe fails
This message checks whether the probe Echo packets are received.
If the number of packets that have no responses reaches the upper limit, trap messages are
sent to a specified NM station.
Trap message sent when an NQA test fails
This message checks whether the test fails.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
NQA Tests
Number:
NQA Flow Remained:1000
6 NQA Configuration