The tunnel type is set to be the MPLS TE tunnel.
Step 5 Run:
lsp-tetunnel tunnel interface-number
The TE tunnel interface to be tested is configured.
Step 6 (Optional) Perform the following as required to configure other parameters for the MPLS TE
Jitter test:
l To configure a protocol used by the LSP ping test, run the lsp-version { rfc4379 | draft6 }
l To configure the response mode of the Echo packet, run the lsp-replymode { no-reply |
l To configure the source IP address, run the source-address ipv4 ip-address command.
l To configure the packet size, run the datasize size command.
l To configure the maximum TTL value of the packet, run the ttl number command.
l To configure the LSP EXP value, run the lsp-exp exp command.
l To configure the padding character of the packet, run the datafill fillstring command.
l To configure the interval for sending the test packets, run the interval { milliseconds
l To configure the percentage of the failed NQA tests, run the fail-percent percent command.
Step 7 Run:
start
The NQA test is started.
Select the start mode as required because the start command has several forms.
l To perform the NQA test immediately, run the start now [ end { at [ yyyy/mm/dd ]
l To perform the NQA test at the specified time, run the start at [ yyyy/mm/dd ] hh:mm:ss
l To perform the NQA test after a certain delay period, run the start delay { seconds second
----End
Issue 01 (2012-03-15)
command.
udp | udp-via-vpls | udp-router-alert | level-control-channel } command.
NOTE
In a uni-directional LSP Ping test, if the lsp-replymode no-reply command is configured, the test
result displays that the test fails regardless of whether the test, actually, is successful or fails. If the test
is successful, the test result also displays the number of the timeout packets. If the test fails, the test
result displays the number of the discarded packets.
interval | seconds interval } command.
NOTE
The minimum interval for sending test packets is one second and the maximum interval is 60 seconds.
hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime { seconds second | hh:mm:ss } ]
command.
The test instance is started immediately.
[ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime
{ seconds second | hh:mm:ss } ] command.
The test instance is started at a specified time.
| hh:mm:ss } [ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } |
lifetime { seconds second | hh:mm:ss } ] command.
The test instance is started after a certain delay.