Configuring Universal Parameters For The Nqa Test Instance - Huawei S9300 Configuration Manual

Table of Contents

Advertisement

S9300&S9300E Terabit Routing Switch
Configuration Guide - Network Management
Commonly, the default configurations of the universal parameters are adopted.
Pre-configuration Tasks
Before configuring universal NQA parameters, create NQA tests correctly.

6.28.2 Configuring Universal Parameters for the NQA Test Instance

This part describes the application of each parameter in the NQA test instance.
Context
Perform the following steps on the NQA client.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
The NQA test instance view is displayed.
Step 3 Configure global parameters for the test instance as required. Before configuring the global
parameters, run the test-type command to specify the test type.
l Run:
l Run:
l Run:
l Run:
Issue 01 (2012-03-15)
agetime hh:mm:ss
The aging time is set for the NQA test instance.
alarm entry-number { lost-packet-ratio | jitter-average | jitter-ds-average |
jitter-sd-average | packet-loss-ds | packet-loss-sd | rtt-average } { absolute
| delta } { falling-threshold threshold-value1 event-entry1 | rising-threshold
threshold-value2 event-entry2 } * [ description ]
Configuration NQA alarms for the NQA test instance.
NOTE
This parameter cannot be configured for Mtrace test instances.
datafill fillstring
The fill string is set for the NQA test instance.
NOTE
This parameter cannot be configured for SNMP, TCP, FTP, HTTP, LSPTrace, DNS, PWE3 Trace, and
MTrace test instances. In the case that the icmp-jitter-type of the ICMPJitter test instanceis is icmp-
echo, this parameter can be configured for ICMPJitter.
datasize size
The packet size is set for the NQA test instance.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 NQA Configuration
356

Advertisement

Table of Contents
loading

This manual is also suitable for:

S9300e

Table of Contents