REP 4.8.5 Stack Full Sensor
Parts List on PL 9.1
Removal
1 Switch off the printer power and disconnect the AC Power Cord.
2 Open the Duplex Unit if one is installed.
3 Remove the Fuser Full Cover (REP 4.1.1).
4 Disconnect the Stack Full Sensor inline connector (P/J133) (Figure 4.8.5a).
5 Remove the two screws that secure the Sensor Bracket to the Offset / Exit Assembly (Figure
4.8.5a). Remove the Sensor Bracket and Actuator.
Replacement
1 Assemble in reverse order.
2 Verify proper operation.
Repair Procedures
Figure 4.8.5a. Stack Full Sensor.
2/2000
4-76
DocuPrint N24, N32, N40, N3225 and N4025