Replacement
1 Make sure the Solenoid Spring and Link Assembly are in place on the Solenoid plunger.
2 Slide the IN Gate Solenoid into the Solenoid Cover, hooking the cutout in the Link Assembly over
the tab in the Cover.
3 Use two screws to secure the Solenoid Cover to the Solenoid.
4 Slide the Damper Bracket, foam rubber against the Solenoid coil, into the Solenoid Cover.
5 Hook the tab on the Cover into the cutout in the Bracket, and slide the Solenoid Assembly
forward to line up the two screw holes. Use two screws to secure the Solenoid Assembly to the
Bracket.
6 Reroute the Solenoid wire harness through the harness clips on the Bracket.
7 Reinstall the Transport Assembly.
8 Reconnect the Finisher to the Printer.