REP 4.7.3 Fuser Exit Sensor
Parts List on PL 9.1
Removal
1 Switch off the printer power and disconnect the AC Power Cord.
2 Open the Duplex Unit, if installed.
3 Remove the EP Cartridge.
4 Remove the Fuser Full Cover (REP 4.1.1).
5 Remove the Offset / Exit Assembly (REP 4.8.1).
6 The Fuser Exit Sensor is attached to the bottom of the Offset / Exit Assembly (Figure 4.7.3a).
Place the Offset / Exit Assembly up side down on a work surface.
7 Remove the Fuser Exit Sensor harness from the cable clamps.
8 Release the two locking tabs on each end of the Fuser Exit Sensor. Remove the sensor.
Replacement
1 Assemble in reverse order.
2 Verify proper operation.
Repair Procedures
Figure 4.7.3a. Fuser Exit Sensor
2/2000
4-70
DocuPrint N24, N32, N40, N3225 and N4025